• Best Prices
  • Best Products
  • Best Brands
  • Best Customer Service

MSA Altair Single Gas Monitor Oxygen (O2)

MSA

MSA Altair Single Gas Monitor Oxygen (O2)

Was: $337.24
Now: $242.00
10092523-1

MSA ALTAIR Single-Gas Detector provides over two years of maintenance-free performance (depending upon alarm minutes used). Long life, cost-effective single-gas detectors offer outstanding dust and water protection and feature a distinctive triple alarm system. Two bright LEDs and piercing audible alarm with standard vibrating alarm help to ensure that no alarm condition goes unnoticed. Rubberized armor housing and one-button operation provide durability and ease of use. Units will not deactivate after two years of operation; instead will perform as long as battery capacity and sensor performance allow. Built-in calibration feature enables users to potentially further extend instrument life. ALTAIR Single-Gas Detectors are part of MSA’s ALTAIR Detector family of products.

Features and Specs:

  • This detector is intended for the use and detection of Oxygen (O2).
  • Factory-calibrated detector with warranted two-year service life (1080 alarm minutes)
  • Maintenance-free; no sensor or battery changes necessary
  • Easy bump check and built-in calibration feature
  • Bump check confirmed with checkmark on instrument LCD, displayed for 24 hours
  • High-capacity battery
  • Built-in IR communications enables interface MSA Link Software
  • Built-in gas delivery adapter for gas response tests (no cal cap to lose)
  • Rated to IP67 for dust and water ingress
  • Range: (Low: 19.5%, High: 23.0%)

Gas Meters are not eligible for returns or exchanges

 

Frequently Asked Questions

Is the MSA ALTAIR Single Gas O2 monitor a good choice for detecting oxygen levels in confined spaces?

Yes. The MSA ALTAIR Single Gas Monitor for Oxygen (O2) is a compact, maintenance-free personal detector built to warn workers of oxygen-deficient or oxygen-enriched atmospheres — the two conditions that make confined spaces, tanks, and vessels dangerous to enter. It alarms low at 19.5% VOL (deficiency) and high at 23.0% VOL (enrichment), using a triple alarm system: two bright LEDs, a piercing audible alarm, and a vibrating alarm so no alert goes unnoticed. It's factory-calibrated, needs no sensor or battery changes, and runs for over two years. It's intrinsically safe (Ex ia IIC T4, Class I Div. 1 Groups A–D), IP67-rated, and wrapped in rubberized armor that survives repeated 20-foot drops onto concrete — a rugged, grab-and-go choice for oil and gas, utilities, and general industry.

What gas does the MSA ALTAIR 10092523 detect, and what are its alarm setpoints?

The MSA ALTAIR Single Gas Detector part number 10092523 detects oxygen (O2). Its factory alarm setpoints are a low (first) alarm at 19.5% VOL for oxygen deficiency and a high (second) alarm at 23.0% VOL for oxygen enrichment; both can be adjusted before activation or via MSA Link Software over IR. The instrument will read oxygen up to 25% but, per MSA, is not certified for use in atmospheres containing more than 21.0% oxygen. Normal ambient oxygen is 20.8%, which is also the recommended calibration value.

Does the MSA ALTAIR Single Gas O2 detector need calibration, charging, or sensor replacement?

No routine servicing is required. The MSA ALTAIR Single Gas O2 is a maintenance-free, factory-calibrated detector — no sensor changes, no battery changes, and no charging for its multi-year life; you activate it and wear it. It has a high-capacity, non-replaceable lithium battery and a built-in gas delivery adapter, so there's no calibration cap to lose. MSA still recommends a bump check before each day's use and a calibration at least every six months (or per local regulations); both can be done on the unit itself thanks to its built-in calibration feature.

Is the MSA ALTAIR Single Gas O2 detector intrinsically safe and certified for hazardous locations?

Yes. The MSA ALTAIR Single Gas O2 detector is intrinsically safe for explosive atmospheres, carrying the approval Ex ia IIC T4, Class I Division 1 Groups A, B, C, and D, and Class II Division 1 Group G. It is also third-party certified to IP67 for dust and water ingress. These ratings make it suitable for hazardous areas such as oil and gas sites, refineries, and utility work where flammable gases or combustible dusts may be present.

How long does the MSA ALTAIR Single Gas O2 detector last, and what is its warranty?

The MSA ALTAIR Single Gas O2 offers over two years of maintenance-free performance, with a warranted two-year service life rated at 1,080 alarm minutes. Its warranty runs two years from the date of activation and is never pro-rated. Importantly, the instrument does not automatically shut down when the 24-month clock runs out — it keeps operating as long as the battery holds charge and it continues to pass a bump test, so units typically last well beyond 24 months. When the battery finally reaches end of life, the detector signals a low-battery warning and is then retired.

How do you bump test and calibrate the MSA ALTAIR Single Gas O2 detector?

You bump test the MSA ALTAIR O2 by pressing the TEST button and applying test gas through its built-in gas delivery adapter; a passing test shows a checkmark on the LCD that stays visible for 24 hours to prove compliance. For oxygen, the daily check can even be done by exhaling on the sensor inlet for a few seconds. Calibration is performed on the unit against 20.8% oxygen in fresh air; MSA recommends calibrating at least every six months, after a physical shock, or if it fails a bump test. For fleet use, it works with the MSA Galaxy GX2 Test Stand, ALTAIR Quick Check Station, and Link Software via built-in IR.

How rugged and durable is the MSA ALTAIR Single Gas O2 detector?

Very. The MSA ALTAIR Single Gas O2 is built for harsh job sites: it survives multiple 20-foot drops onto concrete, is wrapped in rubberized armor for impact protection, and is third-party certified to IP67 against dust and water. It's a compact, lightweight wearable — about 88 × 55 × 41 mm and 0.110 kg (0.243 lb) — with simple one-button operation. A confidence indicator flashes roughly every 60 seconds to confirm the unit is on and working.

Is the MSA ALTAIR Single Gas O2 worth it compared with a basic disposable oxygen detector?

For low total cost of ownership and reliability, yes. Unlike basic disposables, the MSA ALTAIR O2 is factory-calibrated and maintenance-free yet still user-calibratable, so a unit that fails a bump test can be recalibrated instead of scrapped — and it does not auto-shutdown at 24 months, often lasting well beyond. It adds a triple alarm (two LEDs, loud horn, and vibration), IP67 rugged construction, a 25-event datalog, and built-in IR for fleet management with MSA Link and Galaxy GX2. That combination of durability, extended life, and compliance tooling makes it a strong value for teams that monitor oxygen daily.

Where can I buy the MSA ALTAIR Single Gas Oxygen (O2) monitor, and does it ship free?

The MSA ALTAIR Single Gas Monitor for Oxygen (O2), SKU 10092523, is available from Industrial Safety Products (industrialsafetyproducts.com) with free shipping. It ships in black as a factory-calibrated, ready-to-activate single-gas oxygen detector. Note that gas meters are not eligible for returns or exchanges.

How does data logging and MSA Link work on the ALTAIR Single Gas O2?

The MSA ALTAIR Single Gas O2 records its 25 most recent events — alarms, bump tests, calibrations, and errors — in an onboard datalog. Built-in infrared (IR) communications let you transfer this data to a PC running MSA Link Software (or Link Pro), and the unit also works with the ALTAIR Quick Check Station and Galaxy GX2 Test Stand for complete fleet management, testing, and record-keeping across a team of detectors.