Description
- Gas delivery adapter included for fast response tests.
- Built in calibration and bump check with LCD confirmation.
- Easy one-button operation for quick use.



Buy in Bulkand Save Big
Shipping to all Statesto Meet our Customer NeedsDescription
MSA's ALTAIR Single-Gas Detector provides over two years of maintenance-free performance (depending upon alarm minutes used). Long life, cost-effective single-gas detectors offer outstanding dust and water protection and feature a distinctive triple alarm system. Two bright LEDs and piercing audible alarm with standard vibrating alarm help to ensure that no alarm condition goes unnoticed. Rubberized armor housing and one-button operation provide durability and ease of use. Units will not deactivate after two years of operation; instead will perform as long as battery capacity and sensor performance allow. Built-in calibration feature enables users to potentially further extend instrument life. ALTAIR Single-Gas Detectors are part of MSAs ALTAIR Detector family of products.
Features and Specs:
Gas Meters are not eligible for returns or exchanges
Yes. The MSA ALTAIR Single Gas Monitor for Oxygen (O2) is a compact, maintenance-free personal detector built to warn workers of oxygen-deficient or oxygen-enriched atmospheres — the two conditions that make confined spaces, tanks, and vessels dangerous to enter. It alarms low at 19.5% VOL (deficiency) and high at 23.0% VOL (enrichment), using a triple alarm system: two bright LEDs, a piercing audible alarm, and a vibrating alarm so no alert goes unnoticed. It's factory-calibrated, needs no sensor or battery changes, and runs for over two years. It's intrinsically safe (Ex ia IIC T4, Class I Div. 1 Groups A–D), IP67-rated, and wrapped in rubberized armor that survives repeated 20-foot drops onto concrete — a rugged, grab-and-go choice for oil and gas, utilities, and general industry.
The MSA ALTAIR Single Gas Detector part number 10092523 detects oxygen (O2). Its factory alarm setpoints are a low (first) alarm at 19.5% VOL for oxygen deficiency and a high (second) alarm at 23.0% VOL for oxygen enrichment; both can be adjusted before activation or via MSA Link Software over IR. The instrument will read oxygen up to 25% but, per MSA, is not certified for use in atmospheres containing more than 21.0% oxygen. Normal ambient oxygen is 20.8%, which is also the recommended calibration value.
No routine servicing is required. The MSA ALTAIR Single Gas O2 is a maintenance-free, factory-calibrated detector — no sensor changes, no battery changes, and no charging for its multi-year life; you activate it and wear it. It has a high-capacity, non-replaceable lithium battery and a built-in gas delivery adapter, so there's no calibration cap to lose. MSA still recommends a bump check before each day's use and a calibration at least every six months (or per local regulations); both can be done on the unit itself thanks to its built-in calibration feature.
Yes. The MSA ALTAIR Single Gas O2 detector is intrinsically safe for explosive atmospheres, carrying the approval Ex ia IIC T4, Class I Division 1 Groups A, B, C, and D, and Class II Division 1 Group G. It is also third-party certified to IP67 for dust and water ingress. These ratings make it suitable for hazardous areas such as oil and gas sites, refineries, and utility work where flammable gases or combustible dusts may be present.
The MSA ALTAIR Single Gas O2 offers over two years of maintenance-free performance, with a warranted two-year service life rated at 1,080 alarm minutes. Its warranty runs two years from the date of activation and is never pro-rated. Importantly, the instrument does not automatically shut down when the 24-month clock runs out — it keeps operating as long as the battery holds charge and it continues to pass a bump test, so units typically last well beyond 24 months. When the battery finally reaches end of life, the detector signals a low-battery warning and is then retired.
You bump test the MSA ALTAIR O2 by pressing the TEST button and applying test gas through its built-in gas delivery adapter; a passing test shows a checkmark on the LCD that stays visible for 24 hours to prove compliance. For oxygen, the daily check can even be done by exhaling on the sensor inlet for a few seconds. Calibration is performed on the unit against 20.8% oxygen in fresh air; MSA recommends calibrating at least every six months, after a physical shock, or if it fails a bump test. For fleet use, it works with the MSA Galaxy GX2 Test Stand, ALTAIR Quick Check Station, and Link Software via built-in IR.
Very. The MSA ALTAIR Single Gas O2 is built for harsh job sites: it survives multiple 20-foot drops onto concrete, is wrapped in rubberized armor for impact protection, and is third-party certified to IP67 against dust and water. It's a compact, lightweight wearable — about 88 × 55 × 41 mm and 0.110 kg (0.243 lb) — with simple one-button operation. A confidence indicator flashes roughly every 60 seconds to confirm the unit is on and working.
For low total cost of ownership and reliability, yes. Unlike basic disposables, the MSA ALTAIR O2 is factory-calibrated and maintenance-free yet still user-calibratable, so a unit that fails a bump test can be recalibrated instead of scrapped — and it does not auto-shutdown at 24 months, often lasting well beyond. It adds a triple alarm (two LEDs, loud horn, and vibration), IP67 rugged construction, a 25-event datalog, and built-in IR for fleet management with MSA Link and Galaxy GX2. That combination of durability, extended life, and compliance tooling makes it a strong value for teams that monitor oxygen daily.
The MSA ALTAIR Single Gas Monitor for Oxygen (O2), SKU 10092523, is available from Industrial Safety Products (industrialsafetyproducts.com) with free shipping. It ships in black as a factory-calibrated, ready-to-activate single-gas oxygen detector. Note that gas meters are not eligible for returns or exchanges.
The MSA ALTAIR Single Gas O2 records its 25 most recent events — alarms, bump tests, calibrations, and errors — in an onboard datalog. Built-in infrared (IR) communications let you transfer this data to a PC running MSA Link Software (or Link Pro), and the unit also works with the ALTAIR Quick Check Station and Galaxy GX2 Test Stand for complete fleet management, testing, and record-keeping across a team of detectors.